The 3DM-GX4-15™ is a miniature industrial-grade inertial measurement unit (IMU) and vertical reference unit (VRU) with high noise immunity, and exceptional performance.
Product Highlights
Best in Class Performance
Ease of Use
Cost Effective
General |
|||
---|---|---|---|
Integrated sensors |
Triaxial accelerometer, triaxial gyroscope, temperature sensors, and pressure altimeter |
||
Data outputs |
Inertial Measurement Unit (IMU) outputs: acceleration, angular rate, ambient pressure, deltaTheta, deltaVelocity Computed outputs: Adaptive Kalman Filter (AKF): filter status, GPS timestamp, attitude estimates (Euler angles, quaternion, orientation matrix), bias compensated angular rate, pressure altitude, gravity-free linear acceleration, attitude uncertainties, gyroscope and accelerometer bias, scale factors and uncertainties, gravity models, and more. Complementary Filter (CF): attitude estimates (Euler angles, quaternion, orientation matrix), stabilized gravity vector, GPS correlation timestamp |
||
Inertial Measurement Unit (IMU) Sensor Outputs |
|||
Accelerometer |
Gyroscope
|
||
Measurement range |
±5 g (standard) ±16 g (option) |
300°/sec (standard) ±75, ±150, ±900°/sec (options) |
|
Non-linearity |
±0.03 % fs |
±0.03 % fs |
|
Resolution |
<0.1 mg |
<0.008°/sec |
|
Bias instability |
±0.04 mg |
10°/hr |
|
Initial bias error |
±0.002 g |
±0.05°/sec |
|
Scale factor stability |
±0.05 % |
±0.05 % |
|
Noise density |
100 µg/√Hz |
0.005°/sec/√Hz |
|
Alignment error |
±0.05° |
±0.05° |
|
Adjustable bandwidth |
225 Hz (max) |
250 Hz (max) |
|
Offset error over temperature |
0.06% (typ) |
0.05% (typ) |
|
Gain error over temperature |
0.05% (typ) |
0.05% (typ) |
|
Scale factor non-linearity (@ 25° C) |
0.02% (typ) 0.06% (max) |
0.02% (typ) 0.06% (max) |
|
Vibration induced noise |
-- |
0.072°/s RMS/g RMS |
|
Vibration rectification error (VRE) |
-- |
0.001°/s/g2 RMS |
|
IMU filtering |
4 stage filtering: analog bandwidth filter to digital sigma- delta wide band anti-aliasing filter to (user adjustable) digital averaging filter sampled at 4 kHz and scaled into physical units; coning and sculling integrals computed at 1 kHz |
||
Sampling rate |
4 kHz |
4 kHz
|
|
IMU data output rate |
1 Hz to 1000 Hz |
||
Pressure Altimeter |
|||
Range |
-1800 m to 10,000 m |
||
Resolution |
< 0.1 m |
||
Noise density |
0.01 hPa RMS |
||
Sampling rate |
25 Hz |
||
Computed Outputs |
|||
Roll and pitch accuracy |
AKF outputs: ±0.25° RMS (typical) CF outputs: ±0.5° static (typical), ±2.0° dynamic (typical) |
||
Roll and pitch range |
360° about all axes |
||
Roll and pitch resolution |
< 0.01° |
||
Roll and pitch repeatability |
0.3° (typ) |
||
Calculation update rate |
500 Hz |
||
Computed data output rate |
AKF outputs: 1 Hz to 500 Hz CF outputs: 1 Hz to 1000 Hz |
||
Operating Parameters |
|||
Communication |
USB 2.0 (full speed) RS232 (9,600 bps to 921,600 bps, default 115,200) |
||
Power source |
+ 3.2 to + 36 V dc |
||
Power consumption |
100 mA (typ),120 mA (max) with Vpri = 3.2 V dc to 5.5 V dc 550 mW (typ), 800 mW (max) with Vaux = 5.2 V dc to 36 V dc |
||
Operating temperature |
-40 °C to +85 °C |
||
Mechanical shock limit |
500 g (calibration unaffected) 1000 g (bias may change) 5000 g (survivability) |
||
MTBF |
1.2 million hours (Telcordia method I, GL/35C) 0.45 million hours (Telcordia method I, GM/35C) |
||
Physical Specifications |
|||
Dimensions |
36.0 mm x 24.4 mm x 11.1 mm (excluding mounting tabs), 36.6 mm (width across tabs) |
||
Weight |
16.5 grams |
||
Enclosure material |
Aluminum |
||
Regulatory compliance |
ROHS, CE |
||
Integration |
|||
Connectors |
Data/power output: micro-DB9 |
||
Software |
MIP™ Monitor, MIP™ Hard and Soft Iron Calibration, Windows XP/Vista/7/8 compatible |
||
Compatibility |
Protocol compatibility with 3DM-GX3® and 3DM- RQ1-45™ sensor families. |
||
Software development kit (SDK) |
MIP™ data communications protocol with sample code available (OS and computing platform independent) |
General Documentation
Technical Notes
Mechanical Prints (Uncontrolled)
Video